Modular Cold Aisle Containment w/ 45U Server Rack Enclosures and Sliding Doors

Model:MAC20-RS45610


AZE's Aisle containment systems designed to maximize cooling predictability, capacity, and efficiency at the rack, row or room level.The Aisle Containment System is an intelligent thermal containment solution designed to increase cooling system efficiency while protecting critical IT equipment and personnel. AZE minimizes the hot and cold air mixing within the IT environment.

  • 45U 600mmW x 1070mmD server rack
  • 2 rows rack, 10pcs rack per row
  • Dual sliding door 
  • Adapts to varying rack heights, aisle widths, and rack depths 
  • Modular design, flexibity,fast deployment
  • Aisle containment ceilings, walls and end of rows are designed to help maintain optimal operating temperatures in server rooms and data centers
  • Customization available

Overview

This Aisle Containement System include Hot Air Containment (HAC) and Cold Air Containment(CAC). Hot and cold aisle in common consideration for data center. Closed roof plate install in the top of hot aisle/cold aisle to make the area closed. From the point of the whole room air distribution, closed aislephysically isolated hot and cold air,effectively minimize the hot and cold air mixing within IT environment,reduce the waste of hot and cold air, and maxmize cooling efficiency.This containment minimizes the hot and cold air mixing within the IT environment.

 

Aisle Containment Features:

  • Intelligent Fire Safe System      Alerts personnel and drops ceiling panels based on temperature to enable fire suppressions system in the room to extinguish the fire.Once fire signal alarm in room, the top plate will open automatically,and fire extinguishing gases can enter the aisle. 
  • Efficiency & Flexibility               Increases the capacity of the air conditioner by supplying a warmer return air temperature.It supports for varying aisle widths,rack heights, rack depths, and single rows. Supports hot and cold aisle containment.
  • Automatical Door Structure    One-way locking door or safe slide doors secures the hot aisle while allowing for quick exit in case of emergency,the sliding door can be closed automatically,can be installed door access system and can be opened from inside to outside if an emergency occurs.
  • Modular Design & Fast Deployment  Two cabinets and roof ceiling form a unit of self-contained closed space/aisle, it is called hot or cold aisle containment,can be installed seperatedly,provide scalable solutions as demand change or grow.Modular design provides scalable solutions to add cooling as demand increases.
  • Customization   Providing customized solutions for your special requirements can be rapid deployment in your projects

In hot aisle containment systems (HAC), the "hot aisle" is enclosed and cold air is supplied into the enclosure from outside. The hot exhaust air is either routed to the return of an in-row cooling unit (IRC) or allowed to flow upward from within the enclosure into the air conditioning return and away from the equipment via physical barriers and custom ducts. With HAC, the area outside the enclosure is the "cold aisle",  where personnel may more commonly travel. When work needs to be done on the power inputs of the equipment, personnel may have special restrictions to work in the hot aisle contained area. Additionally, this solution may require more custom duct work and can be a little more expensive than CAC systems. On the other hand, HAC is generally understood to be more efficient as it allows for higher return air set temperatures for the air conditioning system.

 

In cold aisle containment systems (CAC), the "cold aisle" is enclosed and cold air is supplied from within the enclosure. The hot exhaust air is expelled from the enclosure into the surrounding environment. A major benefit of this solution is that it is often easier to retrofit into existing data centers, especially on raised floors. It requires less custom duct work since the exhaust air is supplied outside of the enclosure and not returned directly into the AC unit. However, another consideration is that the area outside of the enclosure can get warm quickly so data center operators generally need to set the supply air to a temperature that is cooler than desired for efficient operation.

Aisle Containment Benefits:

  • Eliminate Hot & Cold Air Mixing    Aisle containment encloses either the cold aisle or the hot aisle reducing the amount of space to be cooled and preventing the mixing of hot and cold air.
  • Increase Cooling Capacity     Isolating chilled supply air from hot exhaust air will minimize cooling loss by focusing chilled air on equipment.
  • Increase Energy Savings      Increasing supply air and water temperature setpoints can make protecting sensitive equipment more efficient and cost-effective.
  • Improve Airflow management  Improving airflow will eliminate hotspots and improve the overall cooling potential of data center air conditioning units.

Aisle Containment Main Components:

 

1. Frames Options

  • Rack-Based Frame  The containment frame is built around your existing server rack environment.
  • Freestanding Frame  The containment frame is not dependent on the existing server rack environment. Quickest deployment of our three frame options. You can build the frame first and then put server racks and cabinets in afterwards.

2. Aisle End Doors.

  • Sliding Doors 
  • Mechnical Doors
3. Roof Options:
  • Drop Away Roof Panels   In the event of a fire, the roof panels soften and drop away to allow for unobstructed sprinkler coverage. Designed for quick installation and toolless mounting. They utilize velcro for installation into the enclosure.

  • Tilt Window Roof Panels   In the event of a fire, these roof panels tilt to allow unobstructed sprinkler coverage. Designed for quick installation with an electromagnetic lock controlling the tilt of the panels. Available in single or split tilt configurations depending on spacing requirements of the data center environment.

4. Chimney Options
  • Extendable Chimney   Our vertical exhaust duct (VED) extendable chimney attaches to the top of an 800mm wide server cabinet and provides a sealed pathway for hot exhaust air to flow from the top of the cabinet into an overhead drop ceiling as part of a closed hot air return. 
  • Chimney Passthrough   Our vertical exhaust duct (VED) chimney passthrough attaches to the base of our extendable chimney and has two brushes enabling efficient cable and power cord passthrough. 

Increase energy savings by eliminating hotspots and improving the overall cooling potential of data centers.   

Specification

Environmental  
IP (Ingress Protection) Rating IP20
   
Physical  
Color RAL9001 Black or RAL7035 Grey
Rack option 45U 600mmW x1070mmD
Aisle width 1200mm
Aisle end door option Dual sliding door or mechinical swing door
   
Electronics  
Cooling  In-row cooling or room cooling air conditioner
Power PDU(Basic or intelligent), or power cabinet
Sensors Door Sensor/Water Sensor/Temperature & Humidity sensor/Smoke sensor/Tilt & Shock sensor
Monitoring EMS,KVM Switches,Smart PDU
   
Certifications  
Approvals DIN41491, DIN41494, EIA/ECA-310-E, IEC 294-2, RoHS
Safety CE
   
Warranty  
Standard warranty 1 Year 

How to Order

Model Dimension(WxDxH) Description Containment Components
RS45610 600mmx1070mmx45U Data Center Server Rack Enclosure,45U 600mmWx1070mmD,Black or White Color option Server Rack Enclosure
RS42610CL2W 600mmx1070mmx42U 2-Bay Colocation Server Rack Enclosure,42U 600mmWx1070mmD,Black or White Color option
RS42610CL4W 600mmx1070mmx42U 4-Bay Colocation Server Rack Enclosure,42U 600mmWx1070mmD,Black or White Color option
Basic Rack PDU 0U/1U Provide Reliable Power Distribution to multiple devices from a UPS system, generator or utility (mains) source. Power Distibution( PDU)
Metered Rack PDU 0U/1U Provide real-time remote monitoring of connected loads.
Switched Rack PDU 0U/1U

Provide real-time remote monitoring and remote on/off switching control and of individual outlets for power

cycling, delayed power sequencing,  and outlet use management.

MAC-MD1222 1200mm x 2200mm Mechnical Aisle End Door, Toughened Glass,with TCP/IP door access locking system Aisle Doors
MAC-SD1222 1200mm x 2200mm Sliding Aisle End Door, Toughened Glass,with TCP/IP door access locking system
MAC-RC0612 600mmx1200mm

Modular Top Roof Ceiling Kits(included top roof, supporting bracket for top roof,external decoration panel)

for the 600mmWide rack and 1200mmWide Aisle

Aisle Roof Ceiling
RACABLETRAYM24 600mm Power Cable trough for 24 in. enclosures Top Cabling Accessories
RACABLETRAYN24 800mm Data cable partition for 24 in. enclosures
RACABLELADDER6IN3M 6 inch x 3000mm 6 in. Wide Cable Ladder, 1.5 meters per section, 2 sections per pair
MAC-MONITORSYS n/a

Monitor systems for the aisle containment, including the network EMS unit(can provide the data collection,

fire system and sound/light alarm and monitor the A/C, UPS, and power systems), software,10inch screen

Monitor Systems
RASENSOR-TH n/a Sensor for the temperature and humidity in the aisle Controllers & Sensors
RASENSOR-SM n/a Sensor for the smoke in the aisle
RASENSOR-W n/a Sensor for the water in the aisle

 